For a 100mm shaft (Class "m"), the tolerance is ±0.3mm. If you need tighter than this, you must specify the dimension individually (e.g., 100 +0.02/-0.00 ). Table 2: Angular Dimensions Angles (e.g., a 45° chamfer) have their own rules. The tolerance depends on the length of the shorter side of the angle.

| Nominal Length Range | H (Precision) | K (Standard) | L (Coarse) | | :--- | :--- | :--- | :--- | | ≤10 | 0.02 | 0.05 | 0.1 | | >10 to 30 | 0.05 | 0.1 | 0.2 | | >30 to 100 | 0.1 | 0.2 | 0.4 | | >100 to 300 | 0.2 | 0.4 | 0.8 | | >300 to 1000 | 0.3 | 0.6 | 1.2 | | >1000 to 3000 | 0.4 | 0.8 | 1.6 | iso 2768 general tolerances pdf exclusive

General runout tolerance is always equal to the general tolerance for flatness (for cylindrical parts) or the larger of the two: flatness or perpendicularity. How to Read the Drawing Callout If a drawing says: GENERAL TOLERANCES ISO 2768-mK For a 100mm shaft (Class "m"), the tolerance is ±0